Technical data sheet SOLOPLAN®-30-PLUS Fibre reinforced floor levelling compound
Material number
Contents
Unit of quantity
Packaging
Colour
201337001
25
KG
Bag
Grey
Areas of application To level uneven substrates On critical substrates such as wooden floorboards or mixed substrates For accommodating tiles, boards, mosaic and natural stones or bonded waterproofing For accommodating textile coverings, LVT’s, vinyl and floating laid parquet, laminate and vinyl coverings For interior and exterior use For heated and unheated substrates
Product features self-levelling floor levelling compound CT-C30-F7 after DIN EN 13813 Layer thicknesses ca. 2 - 30 mm Rapid setting Fibre reinforced and low stress
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 1/5
14/05/2025
Technical data sheet SOLOPLAN®-30-PLUS Advantages Fibre reinforced rapid construction progress Versatile
Existing test certificates EMICODE licence
Technical Data Material properties Product components Base material
Consistency Bulk density of fresh mortar Flexural strength (28 days, DIN EN 13813) Abrasion test bonded with PVC in accordance with DIN EN 13892-7 Compressive strength (28 days, DIN EN 13813) Vapour diffusion behaviour Classification of the reaction to fire in accordance with DIN EN 13501-1
1 component system Special cement Cementitious aggregates Additive Powdered approx. 2.1 kg/dm³ ≥ 7 N/mm² RWFC-550 after 16 h at 5 mm layer thickness RWFC-550 after 40 h at 30 mm layer thickness ≥ 30 N/mm² Vapour permeable Efl
Mixing Mixing time Water addition
approx. 3 - 5 minutes approx. 6 - 6.3 l
Application Substrate temperature Pot life Consumption pro m² and mm layer thickness Foot traffic after Ready for covering with tiles Application temperature Hardening time / full resilience
approx. 5 - 25 °C approx. 35 minutes approx. 1.65 kg approx. 2 hours approx. 10 hours approx. 5 - 25 °C approx. 28 hours
Processing equipment Aids/tools Flat trowel Surface rake Stirrer spiked roller Clean mixing bucket
Machine application SOLOPLAN®-30-PLUS can be mechanically applied. For precise information, see the additional Technical Information No. 43.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 2/5
Technical data sheet SOLOPLAN®-30-PLUS Suitable substrate Cement-based screed (CT) Calcium sulphate screeds (CA, CAF) Mastic asphalt screeds (AS) Concrete Wood materials Dry screeds Raised floors Floor levelling compounds Tile bearing elements Firmly adhering tiled finishes
Preparing the substrate Requirement for substrate 1. Dry 2. Load-bearing 3. Firm 4. Grippy 5. Free of cracks 6. Free of adhesion inhibiting substances 7. rigid and free from vibrations
Measures for substrate preparation The substrate must correspond to the load-bearing capacities in accordance with DIN EN1991-1-1.
Preparing the surface 1. Check the application substrate and determine the moisture content using the CM method. 2. Remove impurities, adhesion-reducing substances and binder accumulations/laitance layers. 3. Prime absorbent substrates with ASO-Unigrund-GE, ASO-Unigrund-K or ASO-Unigrund-PLUS. 4. Prime non-absorbent substrates with ASO-Unigrund-S or ASO-Unigrund-PLUS.
Moisture content of the CM measurement
Application Mixing 1. Fill the water into a clean mixing bucket and mix with the powder component with a stirrer to produce a homogeneous, lump-free mass. 2. In between, scrape the unmixed material from the side walls with a trowel and feed it to the mixing process. 3. The mixing time is ca. 3 - 5 minutes.
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 3/5
Technical data sheet SOLOPLAN®-30-PLUS Application 1. Apply SOLOPLAN®-30-PLUS to the primed substrate, and use a suitable tool to distribute it evenly during the pot life. 2. Set level points, so that it will be possible to check the desired height level while the mixture is still fresh. 3. Apply the relevant layer thickness in one application step. 4. Work the fresh levelling compounds with a spiked roller in order to optimise the flow behaviour and accelerate the ventilation process. 5. The setting material should be protected against rapid water removal, e.g. due to a high room temperature, direct solar radiation and draughts! 6. SOLOPLAN®-30-PLUS is ca. 10 hours is walkable with tiles and boards. 7. When it comes to other surface coverings, use the CM method to test the moisture content.
Cleaning tools Clean tools thoroughly with water after use.
Storage conditions Storage Store in a cool and dry place. Min. 12 months in the original canister. Promptly use opened container.
Disposal Product residues can be disposed of in accordance with disposal code AVV 17 01 01.
Emission behaviour / building certification systems Very low emissions in accordance with GEV-EMICODE, which normally results in positive evaluations within the scope of building certification systems in accordance with DGNB, LEED, BREEAM, HQE. Maximum quality level 4, line 8 in accordance with DGNB criteria "ENV 1.2 Risks to the local environment". Suitable for indoor use in accordance with the French VOC Directive and Belgian Royal Decree C-2014/24239.
Notes The installation location must be ventilated. However, draughts and direct solar radiation should be avoided during application and the hardening process. The indoor temperature and floor temperature must be at least +5°C during application, and during the following week! Air dehumidifiers may not be used during the first 3 days! The condition of the substrate is essential to the success of floor levelling. Porous substrates negatively alter the flow behaviour of the smoothing compound, therefore carefully prepare the substrate: clean and prime! In order to minimise pore formation, work ASO®-Unigrund into the substrate in a meticulous manner and allow thorough drying. Calcium sulphate screeds must be protected with the ASO®-Unigrund-GE, ASO®-Unigrund-K, ASODUR®-GBM or ASO®-Unigrund-PLUS primers prior to laying. A moisture measurement must be carried out using the CM method to assess whether it is ready to receive. Direct contact between cement mortar and magnesite screeds leads to the destruction of the magnesite screeds through a chemical reaction known as “magnesite pouring”. Moisture pressure from the rear of the substrate must be prevented through appropriate measures. Mechanically roughen up the magnesite substrate and prime with ASODUR®-GBM epoxy resin. While the coat is still fresh, apply plenty of quartz sand with a grain size of 0.5–1.0 mm. Perform the laying work after a further waiting time of approx. 12 - 16 hours. Remove the unbound quartz sand meticulously. It is imperative to rinse the mixing pump and the hoses in the event of work interruptions! When using a PFT G4/G5 mixing pump, use the standard PFT G4 mixing screw, the D 6-3 rotor and the D 6-3 stator twister, and set the water flow meter to approx. 370–420 l/h. The flow rate would then be ca. 20l/min. In case of larger layer thicknesses, we would recommend using the pump unit, the R7-2.5 rotor and the R7-2.5 stator; in such a case, the water flow meter should be set to ca. 900 l/h. The flow rate would then be ca. 40l/min. The PFT consistency test socket can be used to check and set the correct water addition level on the basis of the slump. It should not exceed the level of 61 cm on a prepared substrate, and it should be monitored continuously during application! Border, field, building separation and movement joints should be carried over to or installed at the designated location; suitable means such as RD-SK50 edging strips should be used to detach them! Crack control joints should be cut in after the SOLOPLAN®-30-PLUS has hardened to the level of up to a third of the introduced layer thickness. We recommend that SOLOPLAN®-30-PLUS be used up to a layer thickness of 10 mm for levelling mastic asphalt screeds of IC10 quality! Only use clean tools and clean water!
SCHOMBURG GmbH & Co. KG · Aquafinstr. 2–8 · D-32760 Detmold (Germany) · Tel. +49-5231-953-00 · Fax +49-5231- 953-333 · schomburg.com 4/5
Technical data sheet SOLOPLAN®-30-PLUS Relevant regulations Planning, inspection of substrates and building site circumstances, laying, grouting and subsequent care of the work must be done in accordance with the relevant DIN standards and recognised rules of technology (e.g. the ZDB Data sheets of the Zentralverband Deutsches Baugewerbe e.V.(German construction Association) in the latest version. Observe applicable safety data sheet! GISCODE: ZP1 Explanations Conformity / Declaration / Verification
The rights of the buyer with regard to the quality of our materials are based on our terms and conditions of sale and delivery. Our technical advice team will be happy to advise you in the case of requirements that exceed the scope of the application described here. In order to be binding, a legally binding written confirmation is required. The product description does not release the user from a duty of care. Lay a test area in the event of uncertainty. This version becomes invalid in the event of a new version being issued.